User's Manual

MOUNTING THE FITTING
To ensure correct operation of the sensor, mount the luminaire that traffic passes across the detector.
INSTALLATION AND WIRING INSTRUCTIONS
Remove the inset back mounting box from the luminaire. Fit the inset back mounting box onto the wall and tighten the screws
at a height that ensures adequate coverage of the area by the infrared detector. The minimum installation height is 2 meters.
And the maximum height is 3 meters.
NOTE: DO NOT REMOVE THE STOPPER UNTIL YOU FINISH THE INSTALLATION. IF THE STOPPER
COMES OFF THE LIGHT, PLEASE REPLACE THE STOPPER OR HOLD THE LIGHT HEAD TO AVOID
SWIVELING AND DAMAGE THE PRODUCT.
WIRING INSTRUCTIONS
Feed the cable through the back mounting box and bush the cable entry to avoid abrasion to the cable.
Connect the earth wire to the connector opposite the
green/yellow cable.
Connect the brown phase conductor active to the
connector opposite the brown cable and tighten the
screws.
Connect the blue neutral conductor to the connector
opposite the blue cable and tighten the screws.
Check that all connections are correct and tight, as
any misconnections will damage the detector.
Re-fit the fitting to the back mounting box.
TOP VIEW
GOOD SENSITIVITY LESS SENSITIVITY