Intelligent Remote Power Management User Manual IPM-01, PDU management software MTS switched PDU MT monitored PDU Designed and manufactured by Austin Hughes UM-IPM-01-Q213V2 www.austin-hughes.
Legal Information First English printing, October 2002 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that results from the use of this equipment. Safety Instructions Please read all of these instructions carefully before you use the device. Save this manual for future reference.
Unpacking The equipment comes with the standard parts shown on the package contents. Check and make sure they are included and in good condition. If anything is missing, or damage, contact the supplier immediately.
Content Over IP connection via IP dongle Part I. Setup and Connection P. 1 < 1.1 > PDU meter setting & cascade < 1.2 > IP dongle installation & connection < 1.3 > Temp. & Humidity connection & specification Part II. IP Configuration and Software P. 7 < 2.1 > IP dongle configuration < 2.2 > InfraPower Manager - IPM-01 FREE PDU management software Part III. Data Export P. 23 Part IV. FAQ P. 27 < 4.1 > InfraPower Manager - IPM-01 < 4.2 > IP dongle < 4.3 > Meter for MTS & MT PDU < 4.
Part I. Seup and Connection < 1.1 > PDU meter setting & cascade LINK 1 OUT PDU cascade port DIP Switch DIP Switch CURRENT (A) 2 Current display 3 Dip switch 225 ON 1 4 DIP 2 3 4 5 6 7 8 Reset button RESET ■ For rackmount PDU, 2 3 4 on the front panel left , 1 on the rear panel Cascaded PDUs setting Using the dip switch no.
< 1.1 > PDU meter setting & cascade 1st level PDU LINK 2nd level PDU CAT. 5 / 6 cable OUT LINK Up to 20 meters CURRENT (A) ON 1 2 3 4 5 6 7 ON 8 1 RESET ■ ■ ■ LINK Up to 20 meters 2 3 4 5 6 225 DIP ON 8 1 7 RESET DIP ON OUT CURRENT (A) 225 DIP ON CAT. 5 / 6 cable OUT CURRENT (A) 225 IP dongle ( refer to P.
< 1.2 > IP dongle installation & connection To remote PDU over IP, users can order IP dongle : IPD-01 IP dongle for vertical PDU Vertical IP dongle installation steps : - slide the IP dongle on the plate above the meter - plug the RJ-45 connector of IP dongle into the LINK port of the 1st level PDU meter - use the CAT.
< 1.2 > IP dongle installation & connection IPD-H01 IP dongle for rackmount PDU Horizontal IP dongle installation steps : - fix the IP dongle on the rear side of rackmount PDU with 4 screws - plug the RJ-45 connector of IP dongle into the LINK port of the 1st level PDU meter - use the CAT. 5 / 6 cable to connect IP dongle to network device To LINK port of the 1st PDU Rear side of rackmount PDU IP dongle To LAN port Customer’s network device ( router or hub ) UM-IPM-01-Q213V2 P.4 www.
< 1.3 > Temp. & Humidity connection & specification MT / MTS meter provides 1 sensor port for Temp. & Humidity monitoring. The user can see the Temp. / Humidity reading not only from the local meter display but also from remote management software. • low profile design with magnetic base for easy affixing to the rack cabinet • Plug n Play • sensor with 2M or 4M cord Temp. & Humid.
< 1.3 > Temp. & Humidity Sensor Connection & Specification Temp. & Humid. Sensor Part no. Temperature Sensitivity IG - TH01 Range 0 to 80°C ( 32 to 176°F ) Accuracy ±1.0°C typical ( ±2°F ) 0.1°C ( 0.2°F ) Resolution Response Time Relative Humidity Sensitivity 5 to 30 sec Range 0 to 100% R.H Accuracy 0 to 100, ±8.0% R.H 20 to 80, ±4.5% R.H. Resolution 1% R.H. Response Time Power Requirement Housing Voltage 8 sec 12VDC, powered by sensor port 20mA Current Consumption Power consumption 0.
Part II. IP Configuration and Software < 2.1 > IP dongle configuration After the completion of IP dongle connection, please take the following steps to configure the IP dongle : 1. Prepare a notebook computer to download the IP setup utilities from the link : http://www.austin-hughes.com/support/utilities/infrapower/IPdongleSetup.msi 2. Double click the IPDongleSetup.msi and follow the instruction to complete the installation. 3. Go to each first level PDU with the notebook computer & a piece of CAT.
< 2.2 > InfraPower Manager - IPM-01, FREE PDU management software InfraPower Manager, IPM-01, is a FREE PDU management software to enhance the features and benefits of the MTS switched and MT monitored PDUs by providing a centralized and remote management platform, and total reporting with detailed logs & event occurrences. InfraPower Manager IPM-01 can support max. 5 concurrent login users and manage multi- IP dongles max. 15, hence the concurrent login users can access & remote PDUs max.
Step 1. Software download Double click the IPM-01.msi and follow the instruction to complete the installation. IPM-01.msi UM-IPM-01-Q213V2 P.9 www.austin-hughes.
Step 1. Software download UM-IPM-01-Q213V2 P.10 www.austin-hughes.
Step 1. Software download Double click the InfraPower Manager - IPM-01 IPM-01 InfraPower Manager and follow the instruction to complete start-up setting. For MS Windows 7 and MS Windows server 2008, it requires to run a program with administrator rights before execution: - Right click InfraPower Manager - IPM-01 , and then select Properties. - Click the Compatibility tab. - Tick the box Run this program as an administrator, and then click OK. UM-IPM-01-Q213V2 P.11 www.austin-hughes.
Step 1. Software Download Completed PostgreSQL password can be changed by user. The password of PostgreSQL must contain at least three of the following four character groups: - English uppercase characters (A through Z) - English lowercase characters (a through z) - Numerals (0 through 9) - Non-alphabetic characters (such as !, $, #, %) UM-IPM-01-Q213V2 P.12 www.austin-hughes.
Step 2. System setup Users can follow below step 1 - 3 to access the management PC and InfraPower Manager IPM-01 Step 1. Open Internet Explorer ( I.E. ), version 7.0 or above Step 2. Enter the IP address of management PC into the address bar ( If fail to access, please ask MIS to check the service port of the management PC ) Step 3.
Step 2. System setup In < Setup > page, the administrator can activate the IP dongle group & set the group command password. UM-IPM-01-Q213V2 P.14 www.austin-hughes.
Step 2. System setup < Alarm > UM-IPM-01-Q213V2 P.15 www.austin-hughes.
Step 2. System setup < Scan > < Refresh > < Temp. > < Backup > < SNMP > UM-IPM-01-Q213V2 P.16 www.austin-hughes.
Step 2. System setup < Sys log > provides last 5000 events in < User >, < Setup >, < Alarm >, < Scan >, < Refresh >, < Temp. >, < Backup > & < SNMP >. < Past sys log > provides a search function in a certain period to find event occurrences in < User >, < Setup >, < Alarm >, < Scan >, < Refresh >, < Temp. >, < Backup > & < SNMP >. UM-IPM-01-Q213V2 P.17 www.austin-hughes.
Step 3. Usage & operation < Status > provides the users a scan function to monitor the PDUs of each IP dongle group one by one & set the alarm amp for the PDU. UM-IPM-01-Q213V2 P.18 www.austin-hughes.
Step 3. Usage & operation < Details > provides a detailed status about a certain PDU. The user can not only set the name & location for PDU & each outlet, but also power ON / OFF the outlets one by one for switched PDU. UM-IPM-01-Q213V2 P.19 www.austin-hughes.
Step 3. Usage & operation < Sensor > < PDU log > provides last 5000 PDU log records about a certain PDU by the user’s selection. The software will generate a PDU log record in every one minute. UM-IPM-01-Q213V2 P.20 www.austin-hughes.
Step 3. Usage & operation < Event > provides last 5000 events about PDU’s configuration & connection and sensor’s configuration & connection in a certain IP dongle group. UM-IPM-01-Q213V2 P.21 www.austin-hughes.
Step 3. Usage & operation < Past log > provides a search function in a certain period to find the log records about a certain PDU or the event occurences about a certain IP dongle group. Completed UM-IPM-01-Q213V2 P.22 www.austin-hughes.
Part III. Data Export 1) Select IP Dongle group. 2) Tick the box of PDU log & ignore the PDU level selection. 3) Enter the period of PDU log to export. (min. 1 day, max. 31 days) 4) Click Export and a Message from webpage dialog box pops up. 5) Click OK to confirm the export process. It may take several minutes to complete. Processing............ UM-IPM-01-Q213V2 P.23 www.austin-hughes.
6) Right click the PDU level below. 7) Select Save Target As to download the PDU log file. UM-IPM-01-Q213V2 P.24 www.austin-hughes.
8) Select the path & click Save to complete the download process. Please take Step 6, 7 & 8 for the other PDU levels one by one. UM-IPM-01-Q213V2 P.25 www.austin-hughes.
• Below is the sample of a PDU log file in MS Excel, CSV format. • User can use the data for analysis purpose. Completed UM-IPM-01-Q213V2 P.26 www.austin-hughes.
Part IV. FAQ < 4.1 > InfraPower Manager - IPM-01 1. What is InfraPower Manager? The InfraPower Manager IPM-01 is a Windows based system to consolidate management of max. 240 PDUs via 15 IP dongles, using a simple web interface which monitors and controls the MTS / MT PDUs in the data center. Authorized users have a secure control over outlets to power ON / OFF at the managed device level. It also provides the detailed PDU and event logged records, and sends alarm email once ampere overloading.
10. Can the MTS / MT PDUs connect the KVM switch? Yes, only CyberView IP KVM switch. In this connection, IP dongle will not be needed. For the details, please find the link below: http://www.austin-hughes.com/support/usermanual/infrapower/UM-IPS-01.pdf 11. Does the IP dongle support web browser access? Yes, the IP dongle features a browser-based built-in graphical user interface (GUI) that can configure, monitor and power control to individual outlets.
< 4.3 > Meter for MTS & MT PDU 1. What is feature of the MT PDU? The MT PDU offers simple & highly reliable power distribution to multiple equipments, and built-in a digital ampere meter indicates the total power consumption of equipment connected to the PDU. The digital ampere meter has an interface which can connect to an IP dongle to the ethernet network, which allows managers to real-time remote monitor the PDU load thru the InfraPower manager (IPM-01). 2.
Part V. Troubleshooting < 5.1 > PDU disconnection 1. GUI shows a certain level PDU disconnected Step 1. PDU power off ? Check the PDU is power ON or not. Step 2. PDU level setting duplicated in the same PDU group ? Check and make sure PDU level is unique and not duplicated in the same PDU group. (Please refer to P.1 for the PDU level setting) 2. GUI shows from a certain level PDU to the last one disconnected Step 1. Cable disconnected, loose or defective ? Check the Cat.
< 5.2 > Replacement, Removal or addition for PDU & IP dongle 1. How to replace the failed IP dongle ? Step 1. Prepare a new IP dongle. Step 2. Disable alarm email in page. Step 3. Replace the failed IP dongle with the new one on 1st level PDU. Step 4. Configure the setting of the new IP dongle same as the old one. (Please refer to P.5 for IP dongle configuration) Step 5. Click Start Connection in page for the relevant IP dongle. Step 6. Enable alarm email in page again. 2.
< 5.2 > Replacement, Removal or addition for PDU & IP dongle 4. How to move out a PDU (without a replacement) ? Step 1. Prepare an appropriate length Cat. 5/6 cable. Step 2. Disable alarm email in page. Step 3. Use the Cat. 5/6 cable to bridge over the removed PDU to minimize log/data loss. Step 4. Power off & unplug the device(s) which connected to the PDU. Step 5. Power off & remove the PDU from connection. Step 6. Click Disable Monitoring in page to stop monitoring the removed PDU.