THE
electrical equipment is designed to give long periods
of
service without need for adjustment
or
cleaning. The
small amount
of
attention which is required is described under "Lubrication and General Maintenance".
Under "General Information" details are given on the operation
of
the various items
of
the equipment and des-
criptions on the method
of
setting the lamp beams and fitting replacements, such as bulbs, high tension cables, bearing
bushes, etc., which may become necessary from time to time.
GENERAL DATA
Battery
Lucas, G.T.W. 7A,
38
ampere hours capacity
at
10
hour discharge rate.
Dynamo
Lucas, Type
C.
39pV-2. Nominal Voltage,
12;
cutting-in speed, 1050-1200 r.p.m. (dyn.).
at
13.0 volts;
maximum output,
19
amps. 13.5 volts
at
2000-2150
r.p.m. (using a
0.
7 ohm resistance load capable
of
carrying
19
amps. without overheating); field resistance,
6. 2 ohms; brush spring tension, 25-22 ozs. (.
7087-
.6237 kg.).
Distributor
Lucas, Type
DM.
2AH4.
Ignition Coil
Lucas, Type Q12 (Saloon and Commercials), Type
B12
(Sports)
Cut-Out
Lucas compensated voltage control, Type RB106:
Cut-in voltage, 12.7-13.3: Drop-off voltage, 9-10:
reserve current,
3-5
amps.
Starter Motor
Lucas, Type M35G/1 controlled
by
pullout knob on
Instrument Panel. Nominal Voltage,
12:
lock torque,
9.3
lb. ft. (1.2858 kgm.); current, 325-345 amps.
at
8. 1-7.7 volts; torque
at
1,000 r.p.m., 4. 9 lb.
ft.
at
200-
220
amps. and 9. 3-8. 9 volts; brush spring tension,
25-15 ozs. (. 7087-.4252 kg.).
Fuse
Unit
Contains two 'live' fuses and two spares.
Fit
50-
amp. fuse between terminals A1-A2 and 35-amp. fuse
between terminals A3-A4.
Traflicators
Type
SF.80. Controlled from the centre boss
of
the steering wheel,
of
the self-cancelling type.
Windscreen Wipers
Type CRT.
14.
Control switch on dash-board,
automatic over-load protection.
Lamp Bulbs
Headlamp: U.K. and R.H.D. countries. Lucas No.
354.
12
volt 42/36 watt. U.S.A. and L.H.D. countries;
Lucas No.
355.
12
volt 42/36 watt. Europe except
France. Lucas No.
350.
12
volt 35/35 watt. (France.
special 3-pin,
not
Lucas.) Side lamps
and
number plate
lamp: Lucas No.
989
12
volt 6 watt. Stop-tail lamps:
Lucas No.
361
12
volt 18/6 watt. Panel lights, ignition
and main beam warning lights: Lucas No.
987
12
volt
2.2
watt. "Trafficator" bulbs: Lucas No.
256
12
volt 3
watt (festoon).
LUBRICATION AND GENERAL MAINTENANCE
After the first 500 miles running.
Distributor
Remove the moulded distributor cover and
turn
the
engine over by hand, carefully observing that the
con-
tacts in the distributor are fully opened. Check the
gap with an
0.014-0.016-in. (.3556-.4064 mm.) gauge.
If
the setting is correct the gauge should be a sliding
fit,
otherwise the contact breaker should be adjusted. To
carry out the adjustment, keep the engine in the position
to give maximum opening
of
the contacts and slacken
the two screws which secure the contact plate to the
distributor body. Move the plate until the gap is set
to the thickness
of
the gauge and then fully tighten the
locking screws. Recheck the gap.