SDS

SAFETY DATA SHEET
Revision: 0
Effective Date: 06/06/16
Page 3 of 5
SECTION 5. FIRE-FIGHTING MEASURES (CONTINUED)
Extinguishing Media:
Water Mist/Fog, Carbon Dioxide, Alcohol Resistant Foam, and Dry Chemical.
Fire Fighting Procedures:
Self-containing breathing apparatus and protective clothing should be worn in fighting
large fires involving chemicals. Shut off all ignition sources. Move containers from fire
area if you can do it without risk. Apply cooling water to sides of containers that are
exposed to flames until well after fire is out. Use flooding amounts of water as fog. Cool
product containers with flooding amounts of water from as far a distance as possible.
Avoid breathing vapors; keep upwind. As with any containerized or pressurized
chemicals, in the event of overheating or direct flame contact, evacuate the area to
minimize hazard of potential explosion.
Unusual Fire Hazards:
Not expected.
Hazardous Decomposition
Products:
Carbon oxides and traces of incompletely burned carbon compounds may be present.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal Precautions:
Avoid contact with eyes.
Protective Equipment:
Refer to Section 8.
Emergency Procedure:
Avoid uncontrolled releases of this material. Where spills are possible, a
comprehensive spill response plan should be developed and implemented.
Methods for Containment
& Cleanup:
Spills should be contained, solidified and placed in suitable containers for disposal in a
licensed facility.
SECTION 7. HANDLING AND STORAGE
Handling:
Flammable. Do not use near fire, flame, or sparks. Do not store at temperatures above
120 °F. Keep out of reach of children. Keep container closed. Avoid contact with eyes.
Provide sufficient ventilation and avoid prolonged skin contact. Do not place cans in trash
compactor. Pressurized container. Do not Puncture.
Storage:
Keep container closed and away from heat and flame sources. Since emptied containers
retain product residues, all hazard precautions given in this MSDS must be observed.
SECTION 8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Exposure Controls:
Component Name
(CAS #)
ACGIH TLV
OSHA PEL
NIOSH IDLH
SD Alcohol 40-B
(64-17-5)
TWA: 1000 ppm
TWA: 1000 ppm
TWA: 1900 mg/m3
IDLH: 3300ppm
TWA: 1000 ppm
TWA: 1900 mg/m3
Engineering Controls: Eyewash Stations; Ventilation Systems; Showers