Specifications

AMIS480P INSTALLATION & OPERATION MANUAL PAGE 7
SETUP
Each channel of the AMIS480P can be wired individually to suit multi-
zone systems. If more than one zone is to receive the same signal, it
can be easily routed to the next channel of the amplifier using the LINK
switches. The channel being linked receives the input signal from the
previous channel. The previous channel may be receiving signal from
its own input or the signal coming from the previous channel. The
volume control only affects the amplifier output, not the input level.
SETUP & TROUBLESHOOTING
TROUBLESHOOTING GUIDE
TROUBLE LIKELY CAUSE REMEDY
Power LED not on Power not reaching amplifier Check mains connection or DC connection
Check mains fuse
Check power switch is on
Thermal indicator on Speaker load bad Check the speaker loads
Amplifier not able to cool itself Check for blockages around the intake grills and
exhaust grills on the rear and sides of the amplifier
Make sure the amplifier has a source of cool air
Distorted sound Output is short circuit Check speaker loads for shorts
Input is overloaded Reduce input level at the source
No sound but amp is on DC fuse(s) blown Refer product to local Australian Monitor dealer
LINK switch is in Check LINK switch position
Channel volume down Check channel volume
Some channels not working with Channel volume down Check channel volume
linked source