INSTALLATION AND OPERATION MANUAL AMIS MP8 8 ZONE MONITOR PANEL
IMPORTANT SAFETY INFORMATION PRÉCAUTIONS DURANT UTILISATION 1. Read these instructions. 1. LISEZ ces instructions. 2. Keep these instructions. 2. Tenez ces instructions. 3. Heed all warnings. 3. Notez tous les avertissements. 4. Follow all instructions. 4. Suivez toutes les avertissements. 5. Do not use this apparatus near water. 5. N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.). 6. Clean only with dry cloth. 6. Nettoyez seulement avec une étoffe sèche.
INTRODUCTION AND CONTENTS MP8 INTRODUCTION 3 The Australian Monitor Installation Series MP8 is a 2 RU monitoring panel that allows you to monitor any of up to 8, constant voltage or low impedance speaker lines. FRONT PANEL 4 REAR PANEL 5 INSTALLATION 6 OPERATION 7 DIMENSIONS 8 BLOCK DIAGRAM 9 SPECIFICATIONS 10 NOTES 11 This can be done via the on-board 2.5” monitor speaker or via the 8 segment VU meter.
FRONT PANEL 1 2 3 1 Monitor Speaker A 2.5” speaker is located behind a cloth grille. No cleaning is required. 2 Monitor Speaker Volume Control This knob controls the volume level of the monitor speaker. NOTE: The Speaker Volume Control does not affect the level of the VU indicator nor does it affect the amplifiers or speaker lines that are connected to the MP8. 3 VU Meter This meter indicates the output level of the currently selected amplifier. The 0dB level is referenced to 100V.
REAR PANEL 1 2 1 Power Socket This 2.1mm socket accepts AC or DC voltage between 12V and 24V. For DC, tip is positive. 2 24VDC In Binding Posts These binding posts provide connection for 24V emergency systems and is not switched by the front panel power switch. The 24VDC IN does not provide trickle charge facility. 3 4 3 Input Terminal Strip Paired connection from each amplifier in the system. The label AMP ‘X’ corresponds with AMPLIFIER ‘X’ on the selector switches.
INSTALLATION Wiring: Connect the speaker output of the first amplifier to INPUT terminals labelled AMP 1, maintaining correct polarity. Connect the speaker load for this amplifier to OUTPUT terminals labelled ZONE 1. Repeat for additional amplifiers and speaker loads. Always use appropriate cable for amplifier to MP8 and MP8 to speaker wiring. NOTE About Grounding: It may be necessary in some circumstances to ground the MP8 to eliminate noise from the monitor speaker.
OPERATION The SIGNAL PRESENT LEDs give a continuous indication of the signal from each of the eight connected amplifiers. Note that very low levels may not be detected. To monitor a particular amplifier, SELECT the desired amplifier. The listening level may be adjusted using the MONITOR SPEAKER VOLUME. The PROGRAM LEVEL meter gives accurate indication of signal from the selected amplifier.
DIMENSIONS REAR PANEL FRONT PANEL 444.0mm [17.5”] 482.0mm [19.0”] 467.0mm [18.4”] 88.0mm [3.5”] 75.8mm [3.0”] SIDE PANEL PAGE 8 210.0mm [8.
BLOCK DIAGRAM AMIS MP8 INSTALLATION AND OPERATION MANUAL PAGE 9
SPECIFICATIONS MONITOR VOLUME LEVELS Input for Max speaker output (10% THD) (Ref 100V) Pot @ 1: -6dB Pot @ 5: -14dB Pot @ 10: -27dB CROSSTALK -72dB @ 1kHz -53dB @ 10kHz SIGNAL PRESENT THRESHOLD -24dB (6.3Vrms) METER REFERENCE SPEAKER TERMINAL CABLE POWER INPUT POWER CONSUMPTION (Max) STANDING CURRENT (ALL VOLTAGES) MAXIMUM CURRENT DIMENSIONS (W x D x H) SHIPPING DIMENSIONS (W x D x H) WEIGHT Net Weight Shipping Weight PAGE 10 0dB 100Vrms rms meter AWG22 (0.75mm) to AWG16 (1.5mm) 12-24V DC 1.
NOTES AMIS MP8 INSTALLATION AND OPERATION MANUAL PAGE 11
ENGINEERED BY AUSTRALIAN MONITOR Address: Level 7, 130 Pitt Street, Sydney NSW 2000 Australia. Website: www.australianmonitor.com.au International enquiries email: international@australianmonitor.com.