Professional Audio Amplifier SY 400 SY 800 SY 1200 SY 1600 SY 400V SY 800V SY 6125 SY 4200 Operation Manual
IMPORTANT! Please read carefully. This operation manual contains important information regarding safety precautions, installation, performance, operation and maintenance of your Synergy-Series power amplifier. You should familiarize yourself with the contents of this manual before operating your amplifier.
Features: > Custom designed, 2RU heavy duty steel chassis. > Open, modular construction for ease of servicing. > Symmetrical layout - even weight distribution. > High current power supply. > High efficiency toroidal mains transformer. > Binding post and 4 pole speaker output connection (no 4 pole speaker outputs on SY400V, SY800V, SY4200 & SY6125). > Stereo or bridged operation (no bridging available on SY400V & SY800V).
Contents Page 1. 2. 3. 4. 5. 6. Introduction Controls, Connectors and Indicators 2.1 Front Panel 2.2 Rear Panel Installation Operation Maintenance Specification 5 6 7 11 14 16 18 20 List of Illustrations Page Figure 1. Block Diagram Figure 2. Front Panel Layout(SY6125, SY1200, SY4200) Figure 3. Rear Panel Layout (SY400, SY1600) Figure 4. Rear Panel Layout (SY6125, SY4200, SY400V) Figure 5.Top Lid Layout (SY6125, SY4200) Figure 6.
Introduction 5 1. Introduction Congratulations on choosing Australian Monitor for your professional amplification requirements. The design of our Synergy-Series Audio Power Amplifiers embraces all the aspects of a well designed amplifier. The visual design, mechanical, electrical and sonic parameters, along with our dedicated manufacturing process, have all been optimized to provide a professional tool that exhibits quality, reliability and longevity. The Synergy-Series amplifiers are 2 unit (3.
Figure 2 MIN MIN LEVEL-A LEVEL-A MAX MAX B OVERLOAD A STATUS MIN LEVEL-B MAX MIN LEVEL-B MAX MIN Australian Monitor OVERLOAD B STATUS A MAX OVERLOAD LEVEL-D MAX MIN LEVEL-E MAX THERMAL FAULT POWER OVERLOAD F STATUS D E MIN MAX STATUS SY 6125 LEVEL-C LEVEL-C C SY 4200 THERMAL FAULT POWER MIN OVERLOAD D STATUS C MIN MIN LEVEL-F LEVEL-D MAX MAX 6 Controls & Connectors 2.
Controls & Connectors 7 Front Panel The Synergy Series differ only slightly across all models and all share the same features on their front panels. Figure 1 shows the panel layout of three Synergy amplifiers, SY4200, SY1200 & SY6125. The SY1200 looks the same as the SY400, SY800, SY1600, SY400V & SY800V. The functions of the controls and indicators are as follows: 3 Overload Indicator 1 Attenuator Level control for your amplifier is provided by a potentiometer on the front panel and indicates gain.
Controls & Connectors NOTE: You should always ensure that the fan grille is kept clean and free from the build up of dust and lint. This will ensure longer operation of your amplifier and reduce the possibility of it prematurely going into thermal shutdown mode. See the section “Installation - Cooling “ on page 14 for recommended cooling procedures. 6 On Indicator This LED will illuminate blue and indicates that the amplifier is on and receiving mains power.
Controls & Connectors 9 Figure 3 Rear Panel Layout (left to right - SY400, SY1600) Australian Monitor
Figure 4 Rear Panel Layout (left to right) - SY400V, SY6125, SY4200 230 V (F3) MAINS 50/ 60 Hz (1333 VA) FUSE 6.3 Amps S.B. CH D MAINS 50/ 60 Hz (1350 VA) 230 V (F3) FUSE 6.3 Amps S.B.
Controls & Connectors 11 Rear Panel 8 Balanced Input A female 3-pin XLR type connector is provided on each input: Pin 1 = Signal Ground; Pin 2 = Hot (non-inverting or in phase); Pin 3 = Cold (inverting or reverse phase). 8a Signal Strapping A male 3-pin XLR type connector is provided (not on SY6125) and wired in parallel with the female input XLR for strapping / looping signal between amplifiers.
Controls & Connectors attenuator. The output from channel B will automatically be of the opposite polarity (reversed phase) and speaker termination should be sourced from the red binding-post outputs. Alternatively, the speaker could be connected to poles 1+ & 2+ of the 4 pole speaker connector (see Installation - Output Wiring on page 11). The SY400V & SY800V cannot be bridged. The SY6125 allows bridging of channels B & C and channels D & E. The bridge switch is located on the rear panel.
Controls & Connectors 13 GND LIFT ( ) GND LIFT ( ) 12 CH A CH B 12 CH C=LP BRIDGE CH-C/D ( ) BRIDGE CH-A/B ( ) SW 1 15 DIP 2 CH C CH D DIP 1 SW 3 SW 2 FILTER ON ( ) LIMITER ON ( ) DIP 3 2 CH A CH C CH D FILTER ON ( ) 2 1 CH-E CH-C 1 CH B 2 CH-B CH-A 1 15 Figure 5 Top Lid Layout (top to bottom - SY4200, SY6125) Australian Monitor DIP 4 DIP 3 DIP 2 DIP 1 LIMITER ON ( ) 2 CH-D LIMITER ON ( ) 1 CH-E 1 2 CH-F 2 CH B DIP 4 1
Installation 3. Installation fans to evacuate the heated air and aid the flow of cool air through the unit. Power Requirements Input Wiring Power consumption for your model of the Synergy Series amplifier is indicated on the rear panel for maximum output. IMPORTANT Do not directly connect pin 1 on the amplifier’s input or strapping XLR, to the amplifier’s chassis, speaker ground or power ground! Ensure that your mains voltage is the same as the rear panel mains voltage marker (+/- 10%).
Installation 15 Binding Post Outputs When terminating to the 4 mm binding post (banana jack) output connectors, banana plugs or bare wires can be used. The red terminal is positive and the black terminal is negative (ground). If running in BRIDGE mode, only the red binding posts are used. For the SY400, SY800, SY1200, SY1600: When bridging, Channel A provides the positive output to the load and channel B provides the negative output to the load.
Operation 4. Operation IMPORTANT All signal source equipment should be adequately earthed. This not only ensures your safety but everybody else's as well. Faults can and do occur in mains connected equipment where the chassis can become “live” if it is not properly earthed. In these instances, the fault in a “floating” (ungrounded) piece of equipment will look for the shortest path to ground, which could possibly be your amplifier's input.
Operation 17 of 600 Ohms or lower to avoid unwanted high frequency loss in the cabling. Input overload occurs at +20.5dBu (8.25 volts). Hum Problems Most equipment is designed for minimum hum when used under ideal conditions. When connected to other equipment, and to a safety earth in an electrically noisy environment, problems may occur.
Maintenance 5. Maintenance Only competent or qualified persons should attempt any service or maintenance of your amplifier. Your Synergy Series amplifier will need minimal maintenance. No internal adjustments need to be made to the unit to maintain optimum performance. To provide years of unhindered operation we suggest a maintenance inspection be carried out on a regular basis, say every 12 months or so.
Australian Monitor
Specifications Model: SY400 Model: SY800 Output Power Output Power Per Channel @ 4 ohms Per Channel @ 4 ohms 0.1% THD 0.1% THD Single channel driven Both channels driven (2 ohm loads not recommended) 240W 200W Bridge mode 8 ohm load (4 ohm bridging not recommended) 400W Voltage Gain Output Impedance @ 1kHz 28.3 <0.
Specifications 21 Model: SY1200 Model: SY1600 Output Power Output Power Per Channel @ 4 ohms Per Channel @ 4 ohms 0.1% THD 0.1% THD Single channel driven Both channels driven (2 ohm loads not recommended) 710W 600W Bridge mode 8 ohm load (4 ohm bridging not recommended) 1200W Voltage Gain Output Impedance @ 1kHz 49.0 <0.
Specifications Model: SY6125 Model: SY4200 Output Power Output Power Per Channel @ 4 ohms Per Channel @ 4 ohms 0.1% THD 0.1% THD Single channel driven All channels driven (2 ohm loads not recommended) Bridge mode 8 ohm load (4 ohm bridging not recommended) Voltage Gain Output Impedance @ 1kHz Frequency response @ 1KHz Rated Power into 4 ohms (-3dB) Single channel driven All channels driven 210W 4 x 200W 2 x 250W Bridge mode 8 ohm load 4 ohm load 2 x 400W 2 x 600W 22.3 <0.
Specifications 23 Model: SY400V Model: SY800V Output Power Output Power Per Channel @ 50 ohms Per Channel @ 25 ohms 0.1% THD 0.
Australian Monitor www.australianmonitor.com.au Distributed by: Audio Telex Communications Pty Ltd ACN 001345482 www.audiotelex.com.au International Enquiries Ph: 612 9647 1411, Fax: 612 9748 2537, E-mail: international@audiotelex.com.au Sydney Ph: (02) 9647 1411, Fax: (02) 9648 3698, E-mail: nsw@audiotelex.com.au Melbourne Ph: (03) 9890 7477, Fax: (03) 9890 7977, E-mail: vic@audiotelex.com.au Brisbane Ph: (07) 3852 1312, Fax: (07) 3252 1237, E-mail: qld@audiotelex.com.