User's Manual

6 General operating instructions
Starting up the radio remote control consists in building a radio link between the transmitting
and the receiving unit.
6.1 Starting up the radio remote control
As required by standard IEC 60204-32, the radio remote control start up is
protected in order to prevent unauthorised use of the machine.
A removable key called Air-KEY guarantees such protection. The radio
remote control cannot work without it.
If the risk assessment requires further protection of the radio remote control
start up, the PIN CODE may be activated.
6.1.1 Start up through Air-KEY (factory setting)
When the receiving unit is powered on, perform the following procedure:
1. Insert a charged battery in the transmitting unit (see paragraph 7.1.1)
2. insert the Air-KEY in the transmitting unit (see paragraph 7.2.1)
3. press the START pushbutton until the green LED blinks slowly.
6.1.2 Start up through Air-KEY and PIN CODE
The PIN CODE provides further protection against unauthorized use of the radio remote control.
It consists of a sequence of commands to be carried out by activating the corresponding
actuators during start-up. The radio remote control will start up only with the correct sequence.
The procedure to enable and modify a PIN CODE is provided in the document “Menu of
Transmitting Unit (MTU)”; you can 󰘰nd this document in the dedicated section on Autec's
website.
When the receiving unit is powered on, perform the following procedure:
1. Insert a charged battery in the transmitting unit (see paragraph 7.1.1)
2. insert the Air-KEY in the transmitting unit (see paragraph 7.2.1).
Consider that the transmitting unit will switch o󰘯 if more than 3 seconds have
passed between the activation of an actuator and the following one.
3. press the START pushbutton until the green LED illuminates
4. activate the commands corresponding to PIN CODE in the correct sequence (PIN 1, PIN
2 and PIN 3 given in the technical data sheet).
a. PIN 1 shall not be included in the start up procedure if it coincides with the START
command.
b. PIN 3 shall not be included in the start up procedure if it coincides with the START
command.
5. press the START pushbutton until the green LED blinks slowly.
AUTEC - Air series
General operating instructions 7
LIAJSE00-00