User's Manual

Dynamic Series description
AUTEC Dynamic Series
LIDYNE00-01.fm Part A: Description, warnings and instructions
A - 1
ENG
DYNAMIC SERIES
Part A: Description, warnings and instructions
1 Dynamic Series description
Autec Dynamic series industrial
radio remote controls are used to
control machines from a dis-
tance, without physical connec-
tions (i.e. wires or connecting
cables) between the user and the
machine.
Each of these industrial radio re-
mote controls consists of a porta-
ble transmitting unit, from which
the user can remotely control the
machine, and a receiving unit in-
stalled on board the machine it-
self.
1.1 Technical data
Command response time ................................................................................. 80 - 130 ms
Active stop cut-in time (typical) ............................................................................. < 130 ms
Active stop cut-in time (maximum)........................................................................... 200 ms
Passive stop cut-in time
1
............................................................................... 0.5 / 1.2 / 2 s
Hamming distance ........................................................................................................ 15
Probability of undetected error.................................................................................. < 10
-15
Typical working range ................................................................................... 100 m (330 ft)
Working range with Low Power function.......................................................... 30 m (100 ft)
Performance Level of safety functions according to EN ISO 13849-1 / EN IEC 62061:
STOP protection ....................................................................... PL e / SIL 3 (4-wire wiring)
STOP protection ....................................................................... PL d / SIL 2 (2-wire wiring)
Protection against unintended movements from the standstill position (UMFS) ....... PL d /
SIL 2
1. Passive stop cut-in time is set by the machine manufacturer (see technical data sheet)