User's Manual

Dynamic Series description
AUTEC Dynamic Series
LIDYNE00-01.fm Part A: Description, warnings and instructions
A - 3
ENG
1.4 Classification of commands
Commands sent by the transmitting unit are classified according to their type.
1.4.1 Command type: analogue, digital or direction command
Commands sent by the transmitting unit can either be analogue or digital.
Analogue commands generate proportional outputs as a function of the position
of the corresponding actuator.
Digital commands switch the status of their corresponding output, according to
the position of the related actuator. This status can either be on or off.
Direction commands are digital commands paired with analogue commands, and
are used to specify the movement direction.
1.4.2 Name of commands
All commands sent by the transmitting unit are identified by abbreviations, which
are also written in the technical data sheet to highlight the match between com-
mands sent and machine functions.
The names of outputs in the receiving unit are not the names of commands.
Check the technical data sheet to know which name they were given.
1.5 Safety functions
Autec radio remote controls are equipped with some functions that provide high
safety levels, in order to safeguard the safety of people and property.
1.5.1 Stop function
The stop function brings the machine to a safe state every time it is necessary to
stop it due to a potentially hazardous situation. This function is either voluntarily
enabled by the user (active stop), as appropriate, or it cuts in automatically and
autonomously (passive stop).
Active stop
Active stop is a function enabled by the STOP pushbutton (see paragraph 6.4).
The transmitting unit sends to the receiving unit a command that immediately
stops the machine. When the STOP pushbutton is pressed, the machine stops in
shorter time than when passive stop cuts in.
Passive stop
Passive stop is a function that cuts in when a fault occurs during operation. When
the radio link is incorrect or interrupted, the receiving unit autonomously stops the
radio remote control. The cut-in time of this function (passive stop cut-in time) is
set by the machine manufacturer (see technical data sheet).