User's Manual

1.6.2 Protection against unintended movements from the standstill position (UMFS)
This safety function protects the system “machine+radio remote control” from unintended
movements, namely machine movements not activated intentionally by the user, but resulting
from possible electrical and mechanical failure of the radio remote control.
Such safety function checks the neutral (rest) position of the actuators that control the
machine's movements. Each time one of those actuators is operated, the transmitting unit
sends both the movement command and the “SAFETY” command. Depending on the speci󰘰c
application, and according to the receiving unit, outputs related to movement and SAFETY
command are wired in series; alternatively the SAFETY command's outputs drive the safety
device provided on the machine.
1.7 Identifying the radio remote control
As required by standard IEC 60204-32, each radio remote control is uniquely identi󰘰ed
through a serial number (S/N).
The S/N is provided in the identi󰘰cation plate on each radio remote control unit.
This is the only reference to be used both for maintenance operations and for declarations
to competent bodies.
These plates must not be:
- removed from their position (removal will invalidate the guarantee)
- altered or damaged (contact Autec for replacement)
10
LIDYNE00-04
Radio remote control description
AUTEC - Dynamic Series