Instruction Manual

LIUDPP000_eng-00 AUTEC
20
WARNING: The maximum working range may vary significantly and
unpredictably when special conditions occur in the working environment (by
way of example: temporary presence of electromagnetic interference and/or
metal ob󰄋ructions).
When a radio link is interrupted:
- All outputs of the Receiving Unit are disabled
- It is not possible to enable or disable the Machine commands through the Transmitting Unit
until the Radio Remote Control is 󰘵arted up again.
By pressing the START pushbutton after an intervention of the automatic 󰄋op
function (passive 󰄋op, see paragraph 4.2.2), the Radio Remote Control 󰄋arts
and the commands that where active before re-activate immediately, as well
as the corresponding functions on the Machine.
The Machine's Manufacturer or those who integrate the Radio Remote Control
in the Machine mu󰄋 take this Radio Remote Control behaviour into account
when carrying out the risk assessment. The Machine Manufacturer or those
who integrate the Radio Remote Control on the Machine mu󰄋 inform the User
if they believe that the reactivation of such Machine functions may entail
hazardous situations that cannot be reduced by reasonable technical measures
implemented on the Machine itself. In this case the User mu󰄋 be appropriately
trained to follow the procedure provided in paragraph "Radio link interruption"
in "Part C" of the Manual.
4.2 Control devices
4.2.1 Start up and switch o󰓐
Start up and switch o󰘯 functions are described in chapter "General instructions for operation"
included in "Part C" of the Instruction Manual. Therefore, please refer to that part of the Manual.
4.2.2 Stop
The 󰘵op is a safety function that brings the Machine to a safe 󰘵ate every time it is necessary
to 󰘵op it due to a potentially hazardous situation.