User's Manual

24
LIDYNE00-07
General operating instructions
AUTEC - Dynamic Series
5.5 Transmittingunitautomaticswitcho󰓐
The transmitting unit automatically switches o󰘯 when:
- the battery is 󰘱at (see paragraph 5.5.1)
- the radio remote control is not used for a certain time (see paragraph 5.5.2)
- the transmitting unit is powered and never switched o󰘯 for eight hours non-stop (see
paragraph 5.5.3).
The green LED on the transmitting unit switches o󰘯.
The POWER LED on the receiving unit switches from blinking to steady on.
Press the START pushbutton to start the radio remote control.
5.5.1 Low battery
The transmitting unit indicates if the battery is not su󰘲ciently charged (the red LED blinks
and an acoustic signal sounds).
The transmitting unit automatically switches o󰘯 after 3.5 minutes from the beginning of the
signal.
The battery needs to be replaced with a charged one (see paragraph 6.1).
5.5.2 When the transmitting unit is not used
If the transmitting unit remains started for a time equal to the “auto switch-o󰘯 time” while none
of these commands is enabled: SAFETY, D2-D10, H1-H8 and L1-L8, then it automatically
switches o󰘯.
The activation of this function and its cut-in time are decided by the machine manufacturer
(see the "Automatic Switch O󰘯" value in the technical data sheet).
5.5.3 Non-stop use
The transmitting unit indicates if it has been used for eight hours non-stop (the red LED blinks
and an acoustic signal sounds).
The transmitting unit automatically switches o󰘯 after 3.5 minutes from the beginning of the
signal.