3.7 Dynamic series technical data
Frequency band in dynamic mode ............................................................... 915 - 928 MHz
Frequency band in static mode .................................................................... 915 - 928 MHz
Transmitting power .............................. meets the requirements for free-license apparatus
Available radio channels................................................................................................ 260
Available radio channels with static mode .................................................................... 260
Channel spacing ....................................................................................................... 50 kHz
Hamming distance ........................................................................................................ 15
Probability of undetected error.................................................................................. < 10
-15
Typical working range....................................................................... 100 m [approx. 330 ft]
Working range with Low Power function............................................. 30 m [approx. 100 ft]
Command response time ................................................................................. 80 - 130 ms
Active stop cut-in time (typical) ............................................................................... < 80 ms
Active stop cut-in time (maximum)........................................................................... 130 ms
Passive stop cut-in time
1
............................................................................... 0.5 / 1.2 / 2 s
Performance Level of safety functions according to EN ISO 13849-1:
STOP protection .................................................................................. PL e (4-wire wiring)
STOP protection .................................................................................. PL d (2-wire wiring)
Protection against unintended movements from the standstill position (UMFS) ......... PL d
1. Passive stop cut-in time is set by the machine manufacturer (see technical data
sheet)