Values of proportional outputs
Restoring factory settings
AUTEC - Dynamic Series
LIUDYN2AC0-00_eng.fm User manual
45
If a speed selector is present on the transmitting unit, calibration is to be per-
formed for each of the selector positions.
If inputs of the module FSAAMI01A are used in the receiving unit to select differ-
ent speeds, calibration must be performed while these inputs are active.
13.2 Restoring factory settings
This procedure is used to restore factory settings for the proportional outputs.
1. Ensure that the transmitting unit is switched off.
2. Power on the receiving unit.
3. Press the TEACH pushbutton and do not release it until the SETUP LED illu-
minates.
4. Press the TEACH pushbutton three times and do not release it at last pres-
sure; the SETUP LED blinks fast: this indicates that factory settings are being
restored.
5. Release the TEACH pushbutton when the SETUP LED is steadily illuminated
again.
If the TEACH pushbutton is released before the SETUP LED is steadily illumi-
nated, factory settings of proportional outputs will not be restored.
6. To leave the procedure, press the TEACH pushbutton on the receiving unit
and do not release it until the SETUP LED switches off.