Data memory backup
Restoring factory settings
46
14 Data memory backup
The receiving unit has two data memories: one is in the DTK connector on the
mother board and one is attached inside the cover (backup data memory).
When data of proportional outputs are modified, they are saved in the data mem-
ory present in the DTK connector.
The data memory in the DTK connector can be copied into a backup data mem-
ory. This is useful in case you need to restore the information contained. In this
case, use the data memory attached inside the cover.
If one of the data memories is lost or damaged, ask the machine manufacturer
for a new one.
Please note that information contained in the data memory in the DTK connector
overwrites the data memory of the BKK connector during the backup procedure.
Perform the following steps to copy the information of the data memory.
1. Make sure that the transmitting unit and the receiving unit are not powered.
2. Open the receiving unit
3. Make sure that a data memory is plugged in the DTK connector
4. Insert the memory attached inside the receiving unit cover in the BKK connector
5. Close the receiving unit
6. Power on the receiving unit: the SETUP LED blinks slowly
7. Press the TEACH pushbutton: the SETUP LED blinks fast (indicating that data
are being copied); release the button when the LED starts blinking slowly again.
If the TEACH pushbutton is released before the SETUP LED starts blinking
slowly again, data contained in the data memory will not be copied.
8. Disconnect power from the receiving unit.
9. Open the receiving unit, remove the data memory from the BKK connector and
attach it inside the cover.
10.Close the receiving unit.
DTK connector
BKK connector
IDK connector