User's Manual

Table Of Contents
AUTEC - Dynamic Series
User manual
Troubleshooting
Solutions in case of malfunction
48
15.3 Solutions in case of malfunction
Identify the radio remote control malfunction according to the light signals on the
units. If the problem persists after the suggested solution has been carried out,
contact the support service of the machine manufacturer.
15.3.1 Malfunction signalled by the transmitting unit
Signals
Possible
reason
Solutions
The green LED does
not switch on when the
START pushbutton is
pressed, even though
both the battery and the
S-KEY are inserted.
The battery is flat.
Replace the battery with a charged
one.
The green LED blinks
fast.
No radio link.
Bring the transmitting unit close to the
receiving unit.
The red LED switches
on for 2 seconds and
then the unit switches
off.
The transmitting unit
does not work correct-
ly.
Contact the support service of the
machine manufacturer.
The red LED blinks
once during start up.
The STOP pushbutton
is locked or damaged.
Unlock the STOP pushbutton.
If this signal persists, contact the sup-
port service of the machine manufac-
turer.
The red LED blinks
twice during start up.
At least one of the
actuators correspond-
ing to commands D2-
D20 is activated or
damaged.
Bring the actuators to the rest posi-
tion. If this signal persists, contact the
support service of the machine manu-
facturer.
The red LED blinks
three times during start
up.
The battery is flat.
Replace the battery with a charged
one.
The red LED blinks four
times during start up.
At least one of the
actuators correspond-
ing to commands A1-
A8 and H1-H8 is acti-
vated or damaged.
Bring the actuators to the rest posi-
tion. If this signal persists, contact the
support service of the machine manu-
facturer.