4.3 Technical data
Command response time 80-130ms
Active 󰘵op time <130ms
(Max.) active 󰘵op time 200ms
Passive 󰘵op time 0.5s
Hamming di󰘵ance ≥15
Probability of undetected error <10
-15
Typical working range 100m (330ft)
Working range with Low Power function 30m (100ft)
Performance Level of the "󰘵op protection" in
compliance with ISO 13849-1 and EN IEC 62061
PL e / SIL 3 (4-wire wiring)
PL d / SIL 2 (2-wire wiring)
Performance Level of the "protection again󰘵
unintended movements from the 󰘵and󰘵ill position
(UMFS)" in compliance with ISO 13849-1 and EN
IEC 62061
PL d / SIL 2
The passive 󰄋op time may be set at 1.2s or 2s if so reque󰄋ed by the Machine
Manufacturer: the User mu󰄋 check the Radio Remote Control's 󰄋op time in
the data provided in the Technical Data Sheet or in the in󰄋ruction manual by
the Machine Manufacturer.
The technical data related to the single Units belonging to the Dynamic+P series are provided
in the speci󰘰c parts of the Manual and in their Technical Data Sheets.
4.4 Identifying the Radio Remote Control
A serial number (S/N) univocally identifies each Radio Remote Control.
The serial number is provided in the identification plate on each Radio Remote Control Unit.
This is the only reference to be used for maintenance operations and for any other situation
when you need to precisely identify the Radio Remote Control.
The serial number mu󰘵 be mentioned in any communication with Autec, its dealers, In󰘵allers,
Maintenance Technicians of the Radio Remote Control and with the people who, in any capacity,
need information, spare parts or technical data concerning the Radio Remote Control.