Instruction Manual

LIUDPP000_eng-00 AUTEC
38
After in󰄋alling and wiring the Receiving Unit, te󰄋 the Machine controlled by
the Radio Remote Control and verify that the operations carried out correspond
exactly to the commands sent, including in particular but not limited to the
functionality of the STOP command.
Make sure that the SAFETY outputs (of UMFS function) only activate after the
Radio Remote Control has 󰄋arted, and when at lea󰄋 one movement command
is sent to the Machine. Also make sure that the SAFETY outputs disable when
all the movement commands are released.
In case of malfunction, disable the sy󰄋em “Machine+Radio Remote Control”
until the problem has been completely solved and the in󰄋allation and
functionality is confirmed to be correct..