Instruction Manual

LIUDPP000_eng-00 AUTEC
52
After using the Radio Remote Control:
- Clean the Transmitting Unit: never use solvents or 󰘱ammable/corrosive materials and do not
use water jet cleaners, or air pressure or 󰘵eam pressure cleaners.
- Store the Transmitting Unit in clean and dry places.
9.2.2 Three-month routine maintenance
At lea󰘵 every three months:
- Check the correct correspondence between the commands that are sent and the manoeuvres
that are carried out by the Machine.
- Make sure that the SAFETY outputs (of UMFS function) only activate after the Radio Remote
Control has 󰘵arted, and when at lea󰘵 one movement command is sent to the Machine. Also
make sure that the SAFETY outputs disable when all the movement commands are released.
This is safety critical maintenance: it is necessary to keep a record (date, signature, comments)
showing that this check has been regularly carried out. Keep the record together with other
in󰘵allation documents.
- Make sure that all the outputs in the Receiving Unit operate correctly, and check that each
output activates when the corresponding operation is enabled and deactivates when the
operation is disabled.
- Start up the Radio Remote Control and check in the Receiving Unit that the STOP outputs
activate. Then, press the STOP pushbutton and check in the Receiving Unit that the STOP
outputs deactivate.
Before te󰄋ing the STOP outputs, make sure that no dangerous situations
may arise due to the activation of the STOP outputs in the Receiving Unit.