Instruction Manual

LIUPJQ000_eng-00AUTEC
33
The cable control mu󰘵 only be connected and disconnected when the Transmitting
Unit is off.
When you finish working with the cable control, disconnect the cable from the
Transmitting Unit and from the Machine, and protect the connectors with their caps.
Follow this procedure to control the Machine with the cable control:
1. Power on the Receiving Unit respecting the voltage limits provided in the technical data (see
"Part D" of the Manual). The POWER LED illuminates.
2. Make sure that the battery is inside the Transmitting Unit and leave it there even though the
power supply comes from the Receiving Unit via the cable control. The battery is not, in any
case, recharged through the cable control: it can only be recharged through its appropriate
battery charger provided together with the sy󰘵em.
3. Connect the cable control to its connector in the Receiving Unit (or where arranged by the
Machine Manufacturer).
4. Connect the cable control to its connector on the Transmitting Unit.
5. Insert the power keyswitch in the Transmitting Unit (see paragraph 8.1).
6. In a Take & Release Radio Remote Control, activate the TAKE command and hold it active
until the Receiving Unit's seven-segment displays show the following signal: "---1" or "---2".
7. Press the START pushbutton and hold it down until the green LED repeats the sequence:
three blinks and a pause. If the red LED illuminates, refer to chapter 11.
When the green LED repeats the sequence: three blinks and a pause, the Radio Remote Control
is active and it can send commands and activate the Machine.
When working with the cable control the radio link is cut off:
8.17 BACK-UP UNIT
If the Transmitting Unit cannot be used, it can be replaced with a Transmitting Unit called BACK-
UP UNIT; you need to ask for it from Autec.
It is identical to the Unit that cannot be used any more; the only difference is the presence of
the plate “BACK-UP UNIT” on the Transmitting Unit.