User's Manual

Diagnostics Operations Diagnosis
42
There are four navigation buttons on top of the Setting mode screen.
Range Button displays the configuration screen on which you can
set the threshold values, an upper limit and a lower limit, for
triggering the buzzer alarm. This function is only applied to the
Waveform Graph display mode.
a) MIN tapping which opens a virtual keyboard, allows you to
enter the required lower limit value
b) MAX tapping which opens a virtual keyboard, allows you to
enter the required upper limit value
c) Buzzer Alarm switches the alarm on and off. The alarm
function makes a beep sound as a reminder whenever the data
reading reaches the preset minimum or maximum point
To set threshold limits for the parameter values
1. Tap the Setting functional button at the bottom of the Live Data
screen.
2. Tap the Range navigation button.
3. Select a parameter item on the left column, or enter the item
name in the Search bar.
4. Tap on the right side of the MIN button, and enter the required
minimum value.
5. Tap on the right side of the MAX button, and enter the required
maximum value.
6. Tap the ON/OFF button on the right side of the Buzzer Alarm
button to turn it on or off.
7. Tap Done to save the setting and return to the Live Data screen;
or tap Cancel to exit without saving.
If the threshold limits are successfully set, two horizontal lines now
appear on each of the data graphs (when Waveform Graph Mode is
applied) to indicate the alarming point. The threshold lines are shown
in different colors than the waveform of the parameters for distinction.
Record Button displays the configuration screen for Record
Setting, on which you can set the trigger type, duration and trigger
point for the data recording function.