Battery Level Indicator Statuses (While Not Charging)
- Solid Green Light - Flashing Green Light - Off
Additional Functions
The additional functions listed below protect and preserve the battery.
Storage Self-Discharge Protection: If the battery is stored in a high-
temperature environment or is idle for 6 days with a high charge level, self-
discharge protection will be activated. The battery will discharge automatically
to a safe level. This is the default setting, and the discharge process takes 2-3
days. While there’s no indication that the battery is performing a self-discharge
cycle, you may notice a slight warming of the battery, which is normal. The
discharge threshold can be customized using the Autel Explorer
TM
app.
Sleep Mode Protection: If the battery power level is low, the battery will
automatically enter sleep mode to prevent damage. In this mode, the battery
will not respond when you push the Power Button. To wake up the battery,
connect it to the charger.
Charging Temperature Detection: If the charging temperature reaches below
C (41°F) or above 45°C (113°F), the battery will stop charging.
Overcurrent Protection: If the charging current exceeds 8A, the battery will
stop charging.
Overcharge Protection: Charging will automatically stop when the battery is
fully charged.
Balance Protection: The voltage of each battery cell is balanced to prevent
overcharging or over-discharging.
Over-Discharge Protection: When the battery is not in use, it will
automatically disconnect the power output function once the self-discharge
cycle is completed. This function is disabled during flight.
Short Circuit Protection: The power supply will be cut off if a short circuit is