Users Manual Part 1

41
4. Select a parameter item from the left column.
5. Select a color from the second column.
6. Select a line thickness from the right column.
7. Repeat step 4 to 6 to edit the waveform for each parameter.
8. Tap Done to save the setting and exit, or tap Cancel to exit without saving.
6. Functional Buttons
The operations of the available functional buttons on the Live Data screen are
described below:
Back returns to the previous screen or exits the function.
Record starts recording the retrieved live data; the recorded data is then stored
as a video clip in the Data Manager application for future reviews. This function can
be triggered automatically at preset threshold values or manually. The triggering
mode and record duration can be configured in the Setting mode of Live Data.
Freeze displays the retrieved data in freeze mode.
Previous Frame moves to the previous frame of frozen data.
Next Frame moves to the next frame of frozen data.
Resume this button displays when the Record or Freeze function is applied. Tap
this button to stop data recording, or exit freeze data mode, and resumes normal
data display mode.
Flag this button displays when the Record function is applied. Tap this button to
set flags to note points of interest when recording data. During playback in Data
Manager, the preset flag will enable a popup window to allow for notes to be
added.
Clear Data tap this button to clear all previously retrieved parameter values.
To Top moves a selected data item to the top of the list.
Graph Merge tap this button to merge selected data graphs (for Waveform
Graph Mode only). This function is very useful when comparing different
parameters.
NOTE
This mode supports Graph Merge for 2 to 3 parameter items only. Select 2 or 3
parameters when creating a graph merge.
To cancel Graph Merge mode, tap the drop-down button on the right side of the