User Manual
Table Of Contents
- Trademarks
 - Copyright Information
 - Disclaimer of Warranties and Limitation of Liabilities
 - For Services and Support:
 - Safety Information
 - Contents
 - Chapter 1 Using This Manual
 - Chapter 2 General Introduction
 - Chapter 3 Getting Started
 - Chapter 4 Diagnostics Operations
 - Chapter 5 Data Manager Operations
 - Chapter 6 MaxiFix Operations
- 6.1 Navigation
- The Header
 - Select Vehicle Button
 - The “Select Vehicle” button on the Header allows you to specify the vehicle which you want to reference on MaxiFix, by selecting each of the vehicle attribute from a sequence of option lists. This feature helps to filter out the searches that allow on...
 - 6.1.1 Terminology
 
 - 6.2 Operations
 
 - 6.1 Navigation
 - Chapter 7 Settings Operations
 - Chapter 8 Shop Manager Operations
 - Chapter 9 Update Operations
 - Chapter 10 VCI Manager Operations
 - Chapter 11 Remote Desk Operations
 - Chapter 12 Support Operations
 - Chapter 13 Training Operations
 - Chapter 14 Quick Link Operations
 - Chapter 15 MaxiScope Operations
- 15.1 Safety Information
 - 15.2 Glossary
 - 15.3 MaxiScope Module
 - 15.4 Screen Layout and Operations
- 15.4.1 Top Toolbar
- Math Channel
 - A math channel is virtual channel generated by mathematical function of the input channel. It can be displayed in a scope or XY view in the same way as an input signal, and like an input signal it has its own measure axis, scaling and color. The MaxiS...
 - Probe
 - A probe is any transducer, measuring device or other accessory that you connect to an input channel of your MaxiScope module.
 - Reference Waveform
 - Recall Reference
 
 - 15.4.2 Functional Buttons
 - 15.4.3 Measurement Grid
 - 15.4.4 Measurement Rulers
 - 15.4.5 Functional Buttons
 
 - 15.4.1 Top Toolbar
 - 15.5 Troubleshooting
 - 15.6 MaxiScope Firmware Update
 
 - Chapter 16 Digital Inspection Operations
 - Chapter 17 Maintenance and Service
 - Chapter 18 Compliance Information
 - Chapter 19 Warranty
 
Digital Inspection Operations    MaxiScope Firmware Update 
116 
4.  Tap Yes  and the selected reference  waveform will appear on the 
scope screen. 
Figure 15-6 Recall Reference Waveform Window 
15.4.2 Functional Buttons 
This  group  of  buttons  is  used  for  configurations  of  channel  activation, 
measurement scale and trigger settings, the operations of which are described 
below: 
  Channel Control Buttons A/B/C/D – tapping each button allows you to 
activate  or  deactivate  the  corresponding  channel;  long  pressing  the 
button  opens  a  window,  which  allows  you  to  select  and  configure 
appropriate probes for specific tests. 
The Channel Control Buttons are displayed in different colors as follows: 
A.  Red 
B.  Green 
C.  Blue 
D.  Pink 
  AC/DC  Coupling  and  Voltage  Scale  Buttons  –  tapping  this  button 
opens  a  dropdown  menu,  on  which  you  can  select  AC  or  DC 
measurements and adjust voltage measurement scales. 
The Auto voltage  scale option enables the scope to adjust the voltage 
scale automatically to capture the signal. 
  AutoScale – tapping this button enables automatic set-up of the voltage 
scale and time base for the signals received. 
  Start/Stop – tapping this button turns on/off the scope. 
  Single – tapping this button activates the Single trigger mode when the 
trigger is on. The Single trigger mode configures the trigger to occur once 
when the scope captures the first signal waveform by the preset trigger 
point. 