User Manual
Table Of Contents
- Trademarks
- Copyright Information
- Disclaimer of Warranties and Limitation of Liabilities
- For Services and Support:
- Safety Information
- Contents
- Chapter 1 Using This Manual
- Chapter 2 General Introduction
- Chapter 3 Getting Started
- Chapter 4 Diagnostics Operations
- Chapter 5 Data Manager Operations
- Chapter 6 MaxiFix Operations
- 6.1 Navigation
- The Header
- Select Vehicle Button
- The “Select Vehicle” button on the Header allows you to specify the vehicle which you want to reference on MaxiFix, by selecting each of the vehicle attribute from a sequence of option lists. This feature helps to filter out the searches that allow on...
- 6.1.1 Terminology
- 6.2 Operations
- 6.1 Navigation
- Chapter 7 Settings Operations
- Chapter 8 Shop Manager Operations
- Chapter 9 Update Operations
- Chapter 10 VCI Manager Operations
- Chapter 11 Remote Desk Operations
- Chapter 12 Support Operations
- Chapter 13 Training Operations
- Chapter 14 Quick Link Operations
- Chapter 15 MaxiScope Operations
- 15.1 Safety Information
- 15.2 Glossary
- 15.3 MaxiScope Module
- 15.4 Screen Layout and Operations
- 15.4.1 Top Toolbar
- Math Channel
- A math channel is virtual channel generated by mathematical function of the input channel. It can be displayed in a scope or XY view in the same way as an input signal, and like an input signal it has its own measure axis, scaling and color. The MaxiS...
- Probe
- A probe is any transducer, measuring device or other accessory that you connect to an input channel of your MaxiScope module.
- Reference Waveform
- Recall Reference
- 15.4.2 Functional Buttons
- 15.4.3 Measurement Grid
- 15.4.4 Measurement Rulers
- 15.4.5 Functional Buttons
- 15.4.1 Top Toolbar
- 15.5 Troubleshooting
- 15.6 MaxiScope Firmware Update
- Chapter 16 Digital Inspection Operations
- Chapter 17 Maintenance and Service
- Chapter 18 Compliance Information
- Chapter 19 Warranty
Digital Inspection Operations MaxiScope Firmware Update
118
4. Tap once on the screen area outside of the Y-axis to finish the
voltage scale adjustment.
To adjust the time base scale
1. Unselect the Y-axis if it’s activated.
2. Use your 2 fingers to adjust the time base with the typical zoom
gestures on the measurement grid area.
15.4.4 Measurement Rulers
The Measurement Rulers allow the voltage and time duration of a waveform to
be measured precisely. There are 2 kinds of measurement rulers: the vertical
Time Ruler and the horizontal Voltage Ruler.
Tap on the Ruler Activator on the bottom right corner of the measurement
grid and drag it across the screen to the desired position, a Time Ruler is
generated.
The Voltage Ruler can be generated in the similar way by clicking the Ruler
Activator on the top left corner and dragging it downwards.
When Measurement Rulers are generated, a Ruler Table showing time and
voltage values for the corresponding channels will be displayed. The Delta
icon refers to the absolute difference between the values of the 2 rulers, which
can be locked by tapping the Lock icon.
Figure 15-8 Measurement Rulers Display