User Manual V2.0 EN190628

35
to turn it on or off.
7. Tap Done to save the setting and return to the Live Data screen; or
tap Cancel to exit without saving.
If the threshold limits are successfully set, two horizontal lines now
appear on each of the data graphs (when Waveform Graph Mode is
applied) to indicate the alarming point. The threshold lines are shown
in different colors than the waveform of the parameters for distinction.
Record displays the configuration screen for Record Setting, on which
you can set the trigger type, duration and trigger point for the data
recording function.
a) Trigger Type – sets the trigger mode for data recording, mainly of two
kinds: Manual and Auto. There are four options available:
1) Manual – allows you to manually start and stop data recording.
2) DTC – auto triggers data recording when any DTC is detected.
3) DTC Check Mode auto triggers data recording when certain
pre-selected DTC types are detected.
4) Parameter auto triggers data recording when any parameter
value reaches the preset threshold.
b) Duration – sets the recording time (for Auto trigger mode only).
c) Trigger Point reserves a relative percentage of a record length
before the data recording start point for reference (for Auto trigger
mode only).
To perform setting for live data record
1. Tap the Setting functional button at the bottom of the Live Data
screen.
2. Tap the Record navigation button.
3. Tap the button on the right of Trigger Type bar and select the
required trigger mode.
4. Tap the button on the right of Duration bar and select a length of
time.
5. Tap the button on the right of Trigger Point bar and select a
relative percentage of a record length to be reserved before the data
recording start point.
6. Tap Done to save the setting and return to the Live Data screen; or
tap Cancel to cancel without saving and exit Setting.
Done confirms and saves the setting, and returns you to the Live Data
screen.
Cancel – cancels the setting operation, and returns you to the Live Data
screen.