User Manual v1.0_EN
132
Channel Color
Identify each channel waveform by color.
Table 7-5 Channel Color Table
Input Channel
Color
A
Red
B
Green
C
Blue
D
Yellow
Amplitude Settings
The amplitude, probe, low-pass filtering and DLC channel settings can be configured
in the Channel control dialog box.
The amplitude settings allow you to set up the oscilloscope to capture signals with
the specified range. If the input signal exceeds the selected range, an over-range
indicator will be displayed. Select Auto to enable the device to adjust the vertical
scale automatically.
It changes the vertical scale, while the horizontal scale is not changed. AC and DC
voltage can be toggled to set up the input circuitry.
Note
The vertical scale is ALWAYS divided into 10 major divisions, and all scale settings
reflect in these 10 divisions. The division set of 10 cannot be changed.
There are two modes available to set the amplitude value.
Mode 1: For example, selecting DC 5V sets the channel amplitude to ±5 DC
(displayed on the right side of the channel control button), the vertical scale range is
from -5V to +5V. The vertical scale is divided into 10 segments, each segment
increases by 1V.