User Manual v1.0_EN

43
Figure 4-19 Sample Waveform Graph Mode Screen
1. Settings Button (SetY) Sets the minimum and maximum value of the Y axis.
2. Scale Button changes the scale values.
There are two scale buttons, displayed above the waveform graph to the right side, which
can be used to change the scale values of the X axis and Y axis of the graph. There are
four scales available: x1, x2, x4 and x8.
3. Edit Button edit the waveform color and the line thickness.
4. Text Button resumes Text Display Mode.
5. Zoom-in Button tap once to display the selected data graph in full screen.
Full Screen Display this option is only available in the waveform graph mode, and
mostly used in Graph Merge status for data comparison. There are three control buttons
available on the top right side of the screen under this mode.
Scale Button tap to change the scale values below the waveform graph. There
are four scales available: x1, x2, x4 and x8.
Edit Button tap to open an edit window, in which you can set the waveform color
and the line thickness displayed for the selected parameter item.
Text Button resumes Text Display Mode.
Zoom-out Button tap to exit full screen display.
To edit the waveform color and line thickness in a data graph
1. Select parameter items to display in Waveform Graph mode.