User Manual v1.0_EN

46
There are four navigation buttons at the top of the Setting mode screen.
Selected Button displays the configuration screen to set the threshold values, an
upper limit and a lower limit, for triggering the buzzer alarm. This function is only
applied to the Waveform Graph display mode.
a) MIN tap this button to display a virtual keyboard to enter the required lower limit
value.
b) MAX tap this button to display a virtual keyboard to enter the required upper limit
value.
c) Buzzer Alarm switches the alarm on and off. The alarm function makes a beep
sound as an alert when the data reading reaches the preset minimum or maximum
point.
To set threshold limits for the parameter values
1. Tap the Setting button at the bottom of the Live Data screen.
2. Tap the Selected navigation button.
3. Select a parameter item from the left column, or enter the item name in the Search
box.
4. Tap the MIN button on the right side, and enter the required minimum value.
5. Tap the MAX button on the right side, and enter the required maximum value.
6. Tap the ON/OFF button on the right side of the Buzzer alarm button to turn it on
or off.
7. Tap Done to save the setting and return to the Live Data screen; or tap Cancel to
exit without saving.
When the limits are successfully set, two horizontal lines display on the data graph
(when Waveform Graph Mode is applied) to indicate the alarm point. The limit lines
are shown in different colors for distinction from the parameter waveforms.
Record displays the configuration screen for record setting, where you can set
the trigger type, duration and trigger point for the data recording function.
a) Trigger type sets the trigger mode for data recording. There are four options
available:
1) Manual allows you to manually start and stop data recording.
2) DTC automatically triggers data recording when any DTC is detected.
3) DTC check mode automatically triggers data recording when certain pre-selected
DTC types are detected.