User Manual

Table Of Contents
36
of time.
5. Tap the
> button on the right of Trigger Point bar and select a
relative percentage of a record length to be reserved before the data
recording start point.
6. Tap Done to save the setting and return to the Live Data screen; or
tap Cancel to cancel without saving and exit Setting.
Done Button confirms and saves the setting, and returns to the Live
Data screen.
Cancel Button cancels the setting operation and returns to the Live
Data screen.
Active Test
The Active Test function is used to access vehicle-specific subsystem and
component tests. Available tests vary depending on the manufacturer, year,
and model, and only the available tests display in the menu.
During an active test, the tester outputs commands to the ECU in order to
drive the actuators. This test determines the integrity of the system or parts
by reading the engine ECU data, or by monitoring the operation of the
actuators, such as switching a solenoid, relay, or switch between two
operating states.
Selecting Active Test opens a menu of test options that varies by make and
model. Selecting a menu option activates the test. Follow on-screen
instructions while performing tests. The content and pattern of the on-screen
information vary according to the type of test being performed. Some toggle
and variable control tests display Active Test Controls at the top of the screen
with data stream information below, or vice versa.