User Manual

117
Baud Rate: The baud rate will display a default value, which needs to be manually
set according to the actual signal to get the correct decoding result.
Threshold: The voltage that defines the transition in either direction between high
logic state and low logic state.
Name: The name of the protocol that you have selected above. The channel and the
corresponding protocol name will display in the scope view after selection.
Display Setting: You can also choose a display mode for the decoded data: Hex or
Binary.
To make the decoding settings
Using CAN High as an example.
1. Tap the Settings button in the top navigation bar. A dialog box opens.
2. Select the Mode option in the dialog box and tap the Oscilloscope Mode.
3. Select the Decoding Setting in the dialog box.
4. Select the channel(s) that you want to set, and then select the "CAN High"
protocol from the dropdown list.
5. For the baud rate and threshold, you can keep the displayed values or manually
enter a value according to the actual signal.
6. Select the Hex or Binary display mode from the dropdown list.
7. Tap "OK" to confirm. The decoding settings are displayed on the screen.