The two angle rulers are positioned to mark the start and end of a cycle. By default,
the start and end angle values are and 720°, which can be configured in the
Ruler Setting box.
The Voltage/Current Ruler can be generated in the similar way by tapping the
Ruler Activator in the upper right corner and dragging it downwards.
When Measurement Rulers are generated, a Ruler Table showing time and voltage
values for the corresponding channels will be displayed. The Delta icon refers to the
absolute difference between the values of the rulers, which can be locked by
tapping the Lock icon. Tap the X button in the upper right corner of the ruler table to
delete all rulers.
Figure 8-30 Sample Rulers Display Screen
To configure angle settings
1. Drag Angle Activator to generate the angle rulers.
2. Tap the start or end angle value to open the Ruler Setting box.
3. Input the desired angle value and the angle partition in the field.