Users Manual Part 3

146
Rising Rate the rate at which the signal level rises
Falling Rate the rate at which the signal level falls
Rise Time the time the signal takes to rise from the lower threshold to the
upper threshold
Fall Time the time the signal takes to fall from the upper threshold to the
lower threshold
X@Max the corresponding value of X axis when the amplitude is the
maximum
X@Min the corresponding value of X axis when the amplitude is the
minimum
Positive Acreage the waveform acreage measured above the zero
baseline
Negative Acreage the waveform acreage measured below the zero
baseline
Full Acreage the positive acreage plus negative acreage
Top Value 90% of the waveform maximum value
Bottom Value 10% of the waveform minimum value
Positive Overshoot the ratio of the difference between the maximum value
and the top value and the amplitude
Negative Overshoot the ratio of the difference between the bottom value
and the minimum value and the amplitude
Positive Pre-shoot the ratio of the difference between the bottom value
and the minimum value and the amplitude
Negative Pre-shoot the ratio of the difference between the maximum value
and the top value and the amplitude
To set the measurements
1. Tap the Measure button at the bottom of the screen to open the
measurement dialog box.
2. Select the channel to be measured.
3. Select the appropriate measurement options. The Whole Track and Ruler
Track can be toggled through the Edit icon in the upper corner of the option.