The ideal position to locate the RT505TX thermostat is about 1.5m
above floor level. It should be mounted in a location where the
thermostat is accessible, reasonably lit and free from extremes of
temperature and draughts. Do not mount the thermostat on an
outside wall, above a radiator or in a location where it may be
subjected to direct sunlight.
To ensure trouble free operation of the Radio Frequency (RF)
signal, always ensure that the programmable thermostat is
mounted away from any possible sources of interference (such as
radios, TV sets, computers, etc.), and is not mounted on or in close
proximity to large metal objects. Installing the RT505TX in
enclosed areas such as cellars and basements is not recommended.
AFTER INSTALLATION
The following table shows the settings of the RT505TX programmable
thermostat after Power on, or after RESET is pressed:
Function Status After Reset or Power On
Operation Mode Normal mode
Room Temperature 22.0 °C, updated within 5 seconds
°C indicator On
Clock 12:00
AM/PM indicator AM
Day of Week indicator M
Program Default factory setting
Set Point Temperature Default factory setting
Program Number indicator 1
SET indicator Off
PROG indicator Off
Frost Protection indicator Off
Heat indicator Off
Low-Battery Warning indicator Off, updated within 5 seconds
Output Relay Off
After Power on, the thermostat will operate in Normal mode (Normal mode
is when the thermostat is displaying the room temperature):
The set point temperature is reset to the default setting
The room temperature display is updated within 5 seconds
The control process starts
The programme number is updated to indicate the running program
RT505TX INSTRUCTION MANUAL