Instruction manual

PROGRAMMING THE RT505TX
The RT505TX offers great versatility with its programming options,
allowing the user to programme the unit to operate on a 5/2 or 7 day
control cycle. The programmable thermostat has a default set of
Programmes that have been designed to meet the needs of most users. If
these default programmes are not suitable for your particular situation,
reprogramming the RT505TX with your own settings is a very
straightforward operation.
Selection of the default programming mode (5/2 or 7 day) is made by
changing the jumper setting on the rear of the RT505TX thermostat, as
previously described within the Installation section of this manual.
5/2 DAY MODE
5/2 day mode is the default programming mode for the RT505TX. With
this mode selected, five different sets of time and set point temperatures
can be set for Weekdays or Weekends.
To review or change a programme, press the SET key when the RT505TX
is in Normal mode. This will change the unit status to Programme Setting
mode.
The LCD display will display programme number 1 and SET PROG, with all
other indicators cleared. The weekdays will be flashing to indicate they
are the selected item and are ready to be adjusted:
Press the UP or DOWN key to select the programme set for either
Weekday or Weekend to be reviewed or adjusted. Pressing the SET key at
any time when in programming mode will return the RT505TX into
Normal mode.
Press the SELECT key to confirm the
Weekday or Weekend selection. Once
this is set, the ‘Hour’ will flash to
indicate that it is the selected item
and is the next item to be adjusted:
RT505TX INSTRUCTION MANUAL
8
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 8