Specifications

Setting Up Call Handling
How to Set Up Call Handling
88
Cisco IOS Survivable Remote Site Telephony Version 3.4 System Administrator Guide
DETAILED STEPS
Command or Action Purpose
Step 1
call-manager-fallback
Example:
Router(config)# call-manager-fallback
Enters call-manager-fallback configuration mode.
Step 2
after-hours block pattern tag pattern [7-24]
Example:
Router(config-cm-fallback)# after-hours block
pattern 1 91900
Defines a pattern of outgoing digits to be blocked. Up to 32
patterns can be defined, using individual commands.
If the 7-24 keyword is specified, the pattern is always
blocked, 7 days a week, 24 hours a day.
If the 7-24 keyword is not specified, the pattern is
blocked during the days and dates that are defined using
the after-hours day and after-hours date commands.
Step 3
after-hours day day start-time stop-time
Example:
Router(config-cm-fallback)# after-hours day mon
19:00 7:00
Defines a recurring time period based on the day of the
week during which calls are blocked to outgoing dial
patterns that are defined using the after-hours block
pattern command.
day—Day of the week abbreviation. The following are
valid day abbreviations: sun, mon, tue, wed, thu, fri,
sat.
start-time stop-time—Beginning and ending times for
call blocking, in an HH:MM format using a 24-hour
clock. If the stop time is a smaller value than the start
time, the stop time occurs on the day following the start
time. For example, “mon 19:00 07:00” means “from
Monday at 7 p.m. until Tuesday at 7 a.m.”
Step 4
after-hours date month date start-time
stop-time
Example:
Router(config-cm-fallback)# after-hours date
jan 1 0:00 0:00
Defines a recurring time period based on month and date
during which calls are blocked to outgoing dial patterns that
are defined using the after-hours block pattern command.
month—Month abbreviation. The following are valid
month abbreviations: jan, feb, mar, apr, may, jun, jul,
aug, sep, oct, nov, dec.
date—Date of the month. Range is from 1 to 31.
start-time stop-time—Beginning and ending times for
call blocking, in an HH:MM format using a 24-hour
clock. The stop time must be larger than the start time.
The value 24:00 is not valid. If 00:00 is entered as an
stop time, it is changed to 23:59. If 00:00 is entered for
both start time and stop time, calls are blocked for the
entire 24-hour period on the specified date.
Step 5
exit
Example:
Router(config-cm-fallback)# exit
Exits call-manager-fallback configuration mode.