2011

Table Of Contents
can also create a report from multiple location codes. AutoCAD Electrical
automatically creates a comma-delimited list for the named location search.
List
Lists drawings that appear to be out-of-date with the wire connection table
of the project.
Freshen Wire Connection Table
Specifies for AutoCAD Electrical to update the wire connection table to include
any out-of-date drawing files.
Format
Changes the format of the extracted data. The subdialog box lists the format
files to select from.
Schematic component wire list
This report extracts the component wire connection data and shows it in a
dialog box. Each entry shows a connection to a component, the wire number,
component tag name, terminal pin number, component location code (if
present), and the layer that the connected wire is on.
Ribbon: Reports tab Schematic panel Reports.
Toolbar: Main Electrical 2
Menu: Projects Reports Schematic Reports
Command entry: AESCHEMATICREPORT
Select Component Wire List from the report list.
Specify whether to process the project, active drawing, or select components.
Options
Specifies to include stand-alone terminals or plug-jack connectors in the report.
Installation Codes to Extract
Extracts only the information for components with specific installation values.
Indicate to process all components that carry part number values, components
Generate schematic reports | 1409