5 Respond to the prompts as follows:
Specify insertion point:
Place the circuit insertion point on the vertical bus wire at line reference 427,
left-click to insert the circuit.
The circuit inserts and updates. Tags automatically update to reflect the
new line reference number, and parent/child relationships defined inside
of the circuit update accordingly.
6 Right-click the M427 coil symbol and select Edit Component.
7 In the Insert/Edit Component dialog box, specify:
Description Line 2: MOTOR NO. 2
Click OK.
8 In the Update Related Components dialog box, click Yes-Update.
Linking the parent coil to the child contactor
1 Open AEGS02.dwg and zoom on the untagged 3-pole motor
contact/overloads on line reference 217.
2 Right-click the M contact and select Edit Component.
The Insert/Edit Child Component displays. Enter the exact parent coil
tag into the Component Tag box to establish the link between the parent
and the child contacts. Currently the Component Tag is M.
3 In the Insert/Edit Child Component dialog box, Component Tag section,
click Project.
4 In the Complete Project list for Family=M dialog box, select M427
HYDRAULIC MOTOR NO. 2 and click OK.