table not found, 0 or entry omitted = use component-spe-
cific only.
Marked with "+[9]" followed by comma-delimited list. Gives
a list of project properties description entries that are
included as a header for generated reports.
LINEx entries for reports
Marked with "+[10]" followed by 0= Combined Installa-
tion/Location component tag mode is off, 1= mode is
Combined Installation/Location/Tag
on, 3= mode is on and include Installation/Location
as a tag prefix.
Marked with "+[11]" followed by 0= allow entered DESC1-
DESC3 to be upper/lower case, missing or 1= force all
entered DESC1-DESC3 values to uppercase.
DESC case mode
Marked with "+[13]" followed by 0 or missing= wire tagging
normal mode (wires combined into one wire number as-
Wire network mode
signment), 1=per wire basis mode (each connected wire
gets its own wire number assignment).
Marked with "+[14]" followed by 0 or missing= add prefix
to TAG when output to reports, 1=suppress adding the
IEC style Installation/Location tag
prefix to TAG for reports, 3=suppress Installation/Location
tag prefix when match drawing-wide Installation/Location
default values for reports. This option is only used when
+[10] above is set to 1 or 3.
Marked with "+[15]" followed by 1= component insert to
auto-fill Installation/Location attributes with drawing de-
Auto-fill Installation/Location
faults, 0 or missing= normal mode (do not auto-fill attribute
values).
Marked with "+[16]" for the format that is to deal with wire
connection entries when there is no existing terminal pin
Schematic- Panel wire format
number text on the panel wiring diagram device footprint,
meaning annotation ends up formatted into an Mtext en-
tity, and "+[17]" for format of data written onto target
TERMxx/WIRENOxx attributes carried on the panel wiring
diagram device footprint.
Marked with "+[18]" followed by 1= auto-hide a wire
number on a wire network when a wire number terminal
Auto-hide wire number