affect components and wire numbers that are already
present on the drawing.
Select inch if your drawing is to use library symbols
from the JIC1/JIC125 libraries or mm full size for the
inch/inch scaled to mm/mm full size
metric scaled symbol libraries. It adjusts the wire
connection trap distance that determines whether
closely spaced wire ends connector not.
Tag/Wire Number Order
Sets the default wire numbering sort order for the active drawing.
You can set sorting on a per-drawing basis and override the project-
Sort Order
wide default setting defined in Properties Wire Numbers dialog
box. For example, you can set the wire numbers to go in a reverse
order from the I/O point on a PLC I/O drawing, but have the wire
numbers going from left to right for non-PLC I/O drawings.
Layers
Defines and manages wire and component layers.Define
NOTE No matter what layer is current, wires always go to a wire
layer and components to component layers.
X zones setup
Use this tool to insert the X grid labels for drawings that use X Zones for the
Format Referencing. You can also change other settings from here (such as
origin) instead of going back into the Drawing Properties dialog box.
Ribbon: Schematic tab Insert Wires/Wire Numbers panel Insert
Ladder drop-down X Zones Setup.
Toolbar: Ladders
Command entry: AEXZONE
Your drawing must be configured for X Zones. Set the Format Referencing in
the Drawing Properties: Drawing Format dialog box to X Zones.