User`s manual
CD Automation srl  REVO S  User’s Manual 
CD-Eng-REVO-S-1PH-60-210A-Solid-State-Relay 
9
4 Technical Specifications 
4.1 General features: 
Cover and Socket material:  PolymericV2 
Utilization Category  AC-51 AC-55b 
IP Code  20 
Method of Connecting  Single Phase Load 
Auxiliary voltage:  12÷24V dc/ac (max 70mA)If requested 
Relay output for Heater Break Alarm 
(only with HB option): 
0.5A a 125VAC 
4.2 Input features: 
Logic input SSR:  5 ÷ 30Vdc 9mA Max (ON ≥ 5Vdc OFF < 4Vdc) 
Logic input SSR with HB option:  4 ÷ 30Vdc 5mA Max (ON ≥ 4Vdc OFF < 1Vdc) 
Analog Input V:  0 ÷ 10Vdc (15KΩ) 
Analog Input A:  4 ÷ 20mA (100Ω) 
Digital Input calib. (only with HB option):  12 ÷ 24V dc/ac (max 4mA) 
4.3 Output features(power device): 
Current
Nominal
Voltage 
range 
(Ue) 
Repetitive 
peak reverse 
voltage 
(Uimp) 
Latching 
current 
Max peak
one cycle
Leakage
current 
I
2
T value 
max 
Frequency 
range 
Power loss
Isolation 
Voltage 
(Ui) 
(A)  (V)  (480V)
(600V)
(mAeff) 
(10msec.) 
(A) 
(mAeff) 
tp=10mse
c 
(Hz) 
I=Inom 
(W) 
Vac 
60  24÷600
1200
1600
450  1000  15  4750  47÷70  65  2500 
90  24÷600
1200
1600
450  2000  15  19100  47÷70  84  2500 
120  24÷600
1200
1600
450  1540  15  11300  47÷70  138  2500 
150  24÷600
1200
1600
450  2000  15  19100  47÷70  162  2500 
180  24÷600
1200
1600
300  4800  15  108000  47÷70  178  2500 
210  24÷600
1200
1600
300  5250  15  128000  47÷70  202  2500 
4.4 Fan Specification (only from 120 to 210A) 
Supply: 230V Standard  Input Power 16W (1 Fan) 
Supply: 115V Option  Input Power 14W (1 Fan) 