Specifications
12 4114V104-UK
Cable resistance per wire (max.), RTD ........  50 Ω 
Sensor current, RTD ....................................  Nom. 0.2 mA 
Effect of sensor cable resistance
(3- / 4-wire), RTD .........................................  < 0.002 Ω / Ω 
Sensor error detection, RTD ....................... Yes  
Short circuit detection, RTD ........................  < 15 Ω
TC input:
Cold junction compensation (CJC) 
  via external sensor in connector 5910 .... 20...28°C ≤ ±1°C
  -20...20°C /
  28...70°C ≤±2°C
  via internal CJC sensor ........................... ±(2.0°C + 0.4°C * Δt)
  Δt=internaltemperature-ambienttemperature 
Sensor error detection, all TC types ........... Ye s 
Sensor error current:
  when detecting ........................................ Nom. 2 μA 
 else .......................................................... 0 μA
Current input:
Measurement range .................................... 0...20 mA 
Programmable measurement ranges ..........  0...20 and 4...20 mA
Input resistance ........................................... Nom. 20 Ω + PTC 50 Ω 
Sensor error detection: 
  Loop break 4...20 mA .............................. Ye s
Voltage input:
Measurement range .................................... 0...12 VDC 
Programmable measurement ranges ..........  0...1 / 0.2...1 / 0...5 / 1...5 /
  0...10 and 2...10 VDC
Input resistance ........................................... Nom. 10 MΩ
Type
Min. 
value
Max. 
value
Standard
B 
E 
J 
K 
L 
N 
R 
S 
T 
U 
W3 
W5 
LR
0°C 
-100°C 
-100°C 
-180°C 
-200°C 
-180°C 
-50°C 
-50°C 
-200°C 
-200°C 
0°C 
0°C 
-200°C
+1820°C 
+1000°C 
+1200°C 
+1372°C 
+900°C 
+1300°C 
+1760°C 
+1760°C 
+400°C 
+600°C 
+2300°C 
+2300°C 
+800°C
IEC 60584-1 
IEC 60584-1 
IEC 60584-1 
IEC 60584-1 
DIN 43710 
IEC 60584-1 
IEC 60584-1 
IEC 60584-1 
IEC 60584-1 
DIN 43710 
ASTM E988-90 
ASTM E988-90 
GOST 3044-84