Installation guide

30 © 2001 Directed Electronics, Inc. Vista, CA
4 IGNITION-CONTROLLED UNLOCKING ON/OFF: When turned on, the vehicle doors will unlock when the igni-
tion is turned off.
5 ACTIVE/PASSIVE LOCKING: If passive arming is selected in Feature 1, then the system can be programmed to
either lock the doors when passive arming occurs, or only lock the doors when the system is armed via the trans-
mitter. Active locking means the system will not lock the doors when it passively arms. Passive locking means
that the system will lock the doors when it passively arms.
NOTE: Remember, when passive arming is selected, the unit will chirp 20 seconds after the last door
is closed. The system does not actually arm or lock the doors until 30 seconds after the door has
been closed.
6 DOOR LOCK PULSE DURATION: Some vehicles require longer lock and unlock pulses to operate the door lock
vacuum pump. Programming the system to provide 3.5 second pulses, will accommodate the door lock interface
in these vehicles. The default setting is 0.8 second door lock pulses.
7 DOUBLE PULSE UNLOCK ON/OFF: Some vehicles require two pulses on a single wire to unlock the doors. When
the double pulse unlock feature is turned on, the unlock relay will provide two pulses instead of a single pulse.
8 DOOR TRIGGER ERROR CHIRP ON/OFF: In the default setting, the door trigger error chirp is programmed off,
so that the system will not report an invalid zone on arming when the door trigger wire is active. This eliminates
the extra chirps that occur when interfacing with vehicles that have exceptionally long dome light delay circuits.
9 NO FUNCTION
10 VALET
®
PULSE COUNT 1-5 PULSES: The system can be programmed to count the number presses of the Valet
®
switch before disarming the security system. The factory default setting is one pulse. The unit can be set for
2-5 pulses by toggling through the two-chirp settings.
GHOST SWITCH
OPTION: For added security, the GRAY wire on the two-pin Valet
®
/program can be
connected to any switch in the vehicle that provides a positive (+) momentary pulse.
11 CHANNEL 3 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/SECOND UNLOCK
OUTPUT/DELAYED ACCESSORY OUTPUT: Channel 3 can be programmed for these output configurations. The unit
is set to the default validity output. To change the configuration, toggle through the different two-chirp settings.