Installation manual
Publication 1394-IN002B-EN-P — February 2004
Troubleshooting Status Indicators   4-9
PositionErrorFault
(Ax: Follow Error)
Axis position error limit 
has been exceeded. This 
fault can be configured for 
status only.
The motor cannot keep up with the position 
command.
• Check motor load for binding.
• Increase position loop proportional gain.
• Increase the allowable following error.
DriveOvercurrent 
Fault
(Ax: I(t) Fault)
The output current is 
exceeding the time-current 
rating.
Accel/decel command from position controller is 
requiring peak current for an excessive amount of 
time.
Change the command profile to reduce speed 
or increase time.
The machine friction, inertial load, and/or viscous 
load is excessive.
• Change the command profile to reduce 
speed or increase time.
• Check for mechanical problems on the 
machine.
The motor has been improperly sized.
• Check motor size for your application.
• Contact your Allen-Bradley Support 
Representative.
A short circuit exists across the drive output 
terminals.
Check wiring between the axis and the motor.
Logic supply circuits have malfunctioned or AC 
output is incorrectly wired.
• Check wiring between the axis and the 
motor.
• Check power wiring between the axis and 
the motor.
• Check resolver wiring between the system 
module and the motor.
PosSoftOvertravel 
Fault
(Ax: +Soft Ovrtrvl)
Axis position exceeded 
maximum software 
positive travel limit.
Positive travel limit set too high.
• Jog motor to within limits.
• Increase travel range limits.
NegSoftOvertravel 
Fault
(Ax: -Soft Ovrtrvl)
Axis position exceeded 
maximum software 
negative travel limit.
Negative travel limit set too low.
• Jog motor to within limits.
• Increase travel range limits.
PosHardOvertravel 
Fault
(Ax: +Hard Ovrtrvl)
Axis tripped positive hard 
overtravel limit switch.
Axis moved beyond the physical travel limits.
• Disable checking and jog motor to within 
limits.
• Move motor manually to within limits.
NegHardOvertravel 
Fault
(Ax: -Hard Ovrtrvl)
Axis tripped negative hard 
overtravel limit switch.
Axis moved beyond the physical travel limits.
• Disable checking and jog motor to within 
limits.
• Move motor manually to within limits.
MotFeedbackFault
(Ax: Mtr Fdbk AQB)
Motor Encoder State Error
Motor encoder has encountered an illegal state 
transition.
• Use shielded cables with twisted pair 
wires.
• Route the feedback away from potential 
noise sources.
• Check the system grounds.
• Replace the motor/encoder.
MotFeedbackFault
(Ax: Mtr Fdbk Comm)
Communication was not 
established with an 
intelligent (i.e. Stegmann) 
encoder.
The encoder feedback signal is lost.
• Check motor feedback wiring
• Reset faults
MotFeedbackFault
(Ax: Mtr Fdbk Loss)
The feedback wiring is 
open, shorted, or missing.
Open or short circuit has occurred on feedback 
wiring.
Check the feedback cable connectors/wiring 
to the system module and motor.
The feedback wiring or termination to system 
module is incorrect.
Check the feedback cable connectors/wiring 
to the system module and motor.
The motor feedback might be bad. Replace the motor feedback.
Fault Message
RSLogix (HIM):