Installation manual
Publication 1394-IN002B-EN-P — February 2004
Installing Your 1394 SERCOS Interface System 1-21
Mounting Your External 
Shunt Resistor Kit
If your 1394 requires a means of dissipating regenerative energy that 
exceeds the capacity of the shunt module, install an External Shunt 
Resistor Kit (refer to Appendix C for catalog numbers).
To install your External Shunt Resistor Kit:
1. Layout the position for your shunt resistor in the enclosure (refer 
to Establishing Noise Zones for panel layout recommendations). 
2. Attach the shunt resistor to the cabinet. The recommended 
mounting hardware is M6 metric (1/4 in.) bolts. Make sure all 
fasteners are properly bonded to the subpanel. Refer to the 
section HF Bonding Your System for proper bonding techniques.
3. Tighten all mounting fasteners.
For mounting dimensions, refer to the Motion Control Selection Guide 
(publication GMC-SG001x-EN-P).
ATTENTION
!
To avoid the hazard of shock or burn and ignition of 
flammable material, appropriate guarding must be 
provided. These resistors can reach temperatures in 
excess of 350° C (662° F). Install per local codes.