Installation manual
Publication 1394-IN002B-EN-P — February 2004
Connecting Your 1394 SERCOS Interface System 3-17
Wiring Logic Power
To wire the logic power connector:
1. Prepare the incoming 24V dc logic power wires for attachment to 
the logic power connector by removing 10 mm (0.375 in.) of 
insulation.
2. Route the 24V dc power wires (W1 and W2) to your 1394 system 
module.
3. Insert the incoming 24V dc logic power wires into the logic power 
connector plug as follows and tighten the connector plug screws.
4. Gently pull on each wire to make sure it does not come out of its 
terminal. Re-insert and tighten any loose wires.
5. Insert the logic power connector plug into the logic power 
connector on the bottom of the system module (refer to Figure 2.1 
for the connector location).
6. Go to Connecting Motor Power, Thermal Switch, and Brake.
Connecting Power Wiring for 22 kW System Modules
The 1394C-SJT22-D system module use IEC terminal blocks instead of 
connectors for making power connections. You will wire the system 
module using the power terminal blocks. Refer to Figure 2.2 for the 
terminal block location.
IMPORTANT
Use caution not to nick, cut, or otherwise 
damage strands as you remove the insulation.
Insert the wires labeled: Into the connector terminals 
labeled:
W1 W1
W2 W2
ATTENTION
!
To avoid personal injury and/or equipment damage, 
ensure installation complies with specifications 
regarding wire types, conductor sizes, branch circuit 
protection, and disconnect devices. The National 
Electrical Code (NEC) and local codes outline 
provisions for safely installing electrical equipment.