Installation manual
Publication 1394-IN002B-EN-P — February 2004
3-22 Connecting Your 1394 SERCOS Interface System
Wiring the Motor Power Connector
To wire your motor power connections:
1. Prepare your conductors by removing the precut insulation or 
stripping approximately 10 mm (0.375 in.) of insulation from the 
end of each wire. 
2. Insert the motor power wires into the axis module terminal block 
as follows and tighten the terminal block screws.
3. Gently pull on each wire to make sure it does not come out of its 
terminal. Re-insert and tighten each loose wire.
4.
5.
IMPORTANT
Use caution not to nick, cut, or otherwise 
damage strands as you remove the insulation.
Insert this wire (number/color): Into this axis 
module terminal 
block:
1326AB/AS 
(resolver) motors:
MP-Series and 
1326AB (M2L/S2L) 
motors:
1 / Black U / Brown U1
2 / Black V / Black V1
3 / Black W / Blue W1
Green/Yellow PE / Green/Yellow PE2
If your motor: Do the following:
Includes the brake option Go to step 5.
Does not include the brake 
option
Go to Understanding Feedback 
and I/O Cable Connections.
For this motor: Using this motor 
power cable:
Do the following:
MP-Series (low inertia) and 
1326AB (M2L/S2L) motors
2090-XXNPMP-xxSxx
2090-CDNBPMP-xxSxx
Go to Wiring the Relay 
Outputs Connector.
1326AB/AS (resolver) 
motors
1326-CPx1-xxx
Go to Wiring the TB1/TB2 
Connectors (1326AB/AS 
Motors).