1
For termination of individual drain wires, use the feedback cable clamp provided and reference Figure 3.10.
2
Thermal switch wires (5 and 9) are in the motor power cable (1326-CPx1-xxx). Route these wires through the noise 
filter (TB1/TB2) and reference Figure 3.10.
Motor 
Connector 
Pin
Resolver
Feedback for 
MPL-Bxxxx-R  
460V Motors
System Module 
Connector Pin
AS2 1
BS4 2
CS1 3
DS3 4
GR1 10
HR2 11
RTS+ 12
STS- 13
Shield Overall Shield Shield Clamp
Motor 
Connector 
Pin
Resolver
Feedback for 
1326AB-Bxxxx-21 
460V Motors
System Module 
Connector Pin 
1
Axis Module 
Connector Pin 
2
Resolver
Feedback for 
1326AB-Bxxxx-21 
460V Motors
System Module 
Connector Pin 
2
AR1 10 TB2-3 TS+ 12
BR2 11 TB2-4 TS- 13
Drain Drain Shield Clamp
DS1 3
ES3 4
Drain Drain Shield Clamp
GS2 1
HS4 2
Drain Drain Shield Clamp