Installation manual
Publication 1394-IN002B-EN-P — February 2004
Connecting Your 1394 SERCOS Interface System 3-31
Figure 3.14
Wiring 1326-CCU-xxx Feedback Cables
Replacement connector housings are included in the system module 
connector kit (part number 1394C-CCK-D). Each terminal has a spring 
type clamping mechanism which firmly grips the bare wire.
Attaching the Cable Shield Clamp
To attach the cable shield clamp:
1. Thread the cable clamp bracket screw into the bottom of the 
system module and tighten using 1.6 Nm (14 lb-in.) torque.
2. Remove another 22 mm (.875 in.) of outer insulation from the 
feedback cable to expose the braided shield underneath for clamp 
attachment (refer to Figure 3.12).
1326-CCU
-xxx
or
1326-CEU-
xxx
1
13
12
11
10
9
8
7
6
5
4
3
2
1
Blade thickness: 
0.5 mm (0.02 in.)
1394 System Module
Feedback Connectors
(bottom view)
Thermal Switch Wires 
from TB2-3 and -4
Bare wires
Wire insulation
Foil shield
Braided shield
Outer insulation
Front
Back
Drain wire
1326-CCU-xxx or 1326-CEU-xxx 
Motor Feedback Cable
Drain Wires (3)
IMPORTANT
To improve the HF bond (and reduce electrical 
noise) between the feedback cable shield and the 
system module chassis ground, use the cable shield 
clamps included with your system module.
IMPORTANT
When cutting into the outer insulation use care 
not to cut into the braided shield underneath.